Union¶
Purpose¶
Union stacks any number of tables, one under the other (the SQL "UNION ALL": all rows are kept, duplicates are not removed). It has three ways of lining up the columns.
When to use it¶
- You have three or more tables with the same layout (twelve monthly extracts, one table per entity).
- The tables are almost the same but a few columns are named differently, and you want to say which column lines up with which.
- You want to stack by column position and ignore headers.
Inputs and outputs¶
| Socket | Carries |
|---|---|
| Input (a single socket on the left that accepts any number of connections) | Every connected table. Connect as many as you need to this one socket. |
| Output (one, on the right) | The stacked table. |
The inputs are stacked in connection order (#1 first). The Input order section lets you change it.
Settings¶
The Config Dock shows "Connect at least one input" until something is connected. After that it has up to three sections.
Union mode ("How columns from the inputs are aligned.")
| Control | What it does | Default |
|---|---|---|
| Mode | Auto by Name: columns with exactly the same name (upper/lower case matter) line up. The output has every name found, in the order first seen; a table without a column gets empty values there. Auto by Position: ignore names; the first column of each table lines up, then the second, and so on. The output uses the first table's column names; if another table is wider, the extra columns are named Extra_4, Extra_5..., and shorter tables are filled with empty values. Manual: you build the output columns yourself. |
Auto by Name |
Input order ("Rows stack #1 first. Reorder with Up/Down or reconnect edges.")
One row per connected input, labelled with its number and where it comes from (for example #1 File Input [out 0]), with two icon buttons per row: Move input N earlier and Move input N later. Each move is an undo step ("Input Order Changed").
Column Mapping (only in Manual mode; "Align each input's column to an output. Blank = Null.")
| Control | What it does |
|---|---|
| Header row | Output, then one heading per input. |
| Output column (text box) | The name of this column in the result. |
| One drop-down per input | Which column of that input goes into this output column. (none) leaves it empty (null) for that input. |
| Add output column (icon) | Adds a row, named New_Column, New_Column_2... |
| Remove output column (icon, per row) | Removes the row. |
The first time you switch to Manual, the grid is pre-filled with the Auto-by-Name result so you can adjust it. Rows with an empty or repeated output name are ignored. Edits apply about a third of a second after you stop.
Worked example¶
Three tables:
Table 1
| Invoice | Amount |
|---|---|
| A1 | 10 |
| A2 | 20 |
Table 2 (the amount is text; has an extra column)
| Invoice | Amount | Note |
|---|---|---|
| B1 | "30" | late |
Table 3 (reference column has a different name)
| Ref | Amount |
|---|---|
| C1 | 5 |
Auto by Name gives:
| Invoice | Amount | Note | Ref |
|---|---|---|---|
| A1 | 10 | null | null |
| A2 | 20 | null | null |
| B1 | 30 | late | null |
| null | 5 | null | C1 |
Amount is whole numbers in two tables and text in the other, so the whole column becomes text (shown as numbers here for readability). The node's tooltip says: Column 'Amount' has conflicting types (Int64, String); coerced to String. Ref is a separate column from Invoice; to line them up use Manual.
Manual with two tables, Table 1 = (Invoice, Amount) and Table 4 = (Ref, Total, Note):
| Output | Table 1 | Table 4 |
|---|---|---|
| Doc | Invoice | Ref |
| Value | Amount | Total |
| Comment | (none) | Note |
gives
| Doc | Value | Comment |
|---|---|---|
| A1 | 10 | null |
| B1 | 20 | x |
(Table 1 supplies A1/10; Table 4 supplies B1/20/x.)
Auto by Position on the same two tables (Table 1 has two columns, Table 4 three) gives column names from Table 1 plus Extra_3:
| Invoice | Amount | Extra_3 |
|---|---|---|
| A1 | 10 | null |
| B1 | 20 | x |
Edge cases and limits¶
- One connected input passes through unchanged.
- Row cap: none. The live preview shows the first 100 rows of the result; Run stacks everything. See Live preview and Run.
- Type conflicts. When the same column (or position, or Manual row) has different types across inputs, it is converted to text for all of them, and a warning appears in the node's tooltip. Text-to-text and number-to-number needs no conversion.
- Names are case-sensitive in Auto by Name:
Amountandamountbecome two columns. - Disconnected or empty upstream nodes are skipped. If none produces data the tooltip says "Upstream nodes produced no output".
- Manual with no valid rows falls back to the Auto-by-Name layout.
- If stacking fails for any reason the node is marked invalid with the tooltip "Union failed" (the technical detail is in the log).
- Adding or removing a connection while the Manual grid is open rebuilds the grid so that the new input's columns appear.
Errors and messages¶
Union does not raise TD- codes. It reports on the node tooltip:
| Message | What it means |
|---|---|
| Connect at least one input | Nothing is connected. |
| Upstream nodes produced no output | The connected nodes have errors or no data; fix them first. |
| Union failed | The tables could not be stacked. Check the column types; look in the log for details. |
| Column 'X' has conflicting types (...); coerced to String. | A warning, not an error. The column was turned into text. |
Tips¶
- Prefer Auto by Name when the tables come from the same system. Use Manual when the tables come from different systems and the same field has different names.
- To record which table a row came from, add a source column to each input before the Union (a Formula writing the table name), or have File Input add the filename.
- If you only have two tables, Append is simpler.
Back to the Join node index.